Drolet Classic Especificaciones

Busca en linea o descarga Especificaciones para Estufa de leña Drolet Classic. Drolet Classic Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 49
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
READ AND KEEP THIS MANUAL FOR REFERENCE
45626A
Printed in Canada 20-11-2013
Installation and Operation Manual
Classic With Blower
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOOD STOVE
Safety tested according to ULC S627
and UL 1482 Standards
by Intertek Testing Services
www.drolet.ca
Stove Builder International Inc.
250, rue de Copenhague, St-Augustin-de-Desmaures
(Quebec) Canada G3A 2H3
Tel: (418) 878-3040 Fax: (418) 878-3001
This manual is available for free download on the manufacturer’s web site. It is a
copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this
manual from time to time and cannot be responsible for problems, injuries, or damages
arising out of the use of information contained in any manual obtained from unauthorized
sources.
Vista de pagina 0
1 2 3 4 5 6 ... 48 49

Indice de contenidos

Pagina 1 - Classic With Blower

READ AND KEEP THIS MANUAL FOR REFERENCE 45626A Printed in Canada 20-11-2013 Installation and Operation Manual Classic With Blower US ENVIRONMENTA

Pagina 2

Classic With Blower Installation and Operation Manual 10 3 Fuel 3.1 Materials That Should Not be Burned • GARBAGE OF ANY KIND, • COAL OR CHARCOA

Pagina 3

Classic With Blower Installation and Operation Manual 11 wouldn’t hold a fire overnight unless they were fed large pieces of hardwood. That is no lo

Pagina 4

Classic With Blower Installation and Operation Manual 12 Wood should be split to a range of sizes, from about 3” to 6” (75 mm to 150 mm) in cross se

Pagina 5 - 1 Safety Information

Classic With Blower Installation and Operation Manual 13 3.2.6 Judging Firewood Moisture Content You can find out if some firewood is dry enough to

Pagina 6 - 2 General Information

Classic With Blower Installation and Operation Manual 14 4 Operating Your Stove 4.1 Your First Fires Two things will happen as you burn your first

Pagina 7

Classic With Blower Installation and Operation Manual 15 DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED DURING IGNITION. ALWAYS

Pagina 8

Classic With Blower Installation and Operation Manual 16 4.3 Maintaining Wood Fires 4.3.1 General Advice Wood heating with a space heater is very d

Pagina 9

Classic With Blower Installation and Operation Manual 17 dispersed, they should be retained in the closed container until all cinders have thoroughl

Pagina 10

Classic With Blower Installation and Operation Manual 18 When you burn a new load of wood hot to heat up the wood, the stove and the chimney, the re

Pagina 11

Classic With Blower Installation and Operation Manual 19 4.3.6 Building Different Fires for Different Needs Using the air control is not the only w

Pagina 12

Classic With Blower Installation and Operation Manual 2 THANK YOU FOR CHOOSING THIS DROLET WOOD STOVE As one of North America’s largest and most re

Pagina 13 - 3.3 Manufactured Logs

Classic With Blower Installation and Operation Manual 20 4.3.6.4 Maximum Burn Cycle Times The burn cycle time is the period between loading wood on

Pagina 14 - 4 Operating Your Stove

Classic With Blower Installation and Operation Manual 21 5 Maintaining Your Wood Heating System 5.1 Stove Maintenance Your new stove will give man

Pagina 15

Classic With Blower Installation and Operation Manual 22 5.1.2 Door adjustment In order for your stove to burn at its best efficiency, the door must

Pagina 16 - 4.3 Maintaining Wood Fires

Classic With Blower Installation and Operation Manual 23 Place the door face-down on something soft like a cushion of rags or piece of carpet. Remov

Pagina 17

Classic With Blower Installation and Operation Manual 24 Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glas

Pagina 18

Classic With Blower Installation and Operation Manual 25 It is recommended to clean thoroughly the chimney system at the end of every heating season

Pagina 19

Classic With Blower Installation and Operation Manual 26 PART B - INSTALLATION 6 Safety Information 6.1 Summary of Installation Cautions and Warnin

Pagina 20

Classic With Blower Installation and Operation Manual 27 7 Clearances to Combustible Material The clearances shown in this section have been determ

Pagina 21 - 5.1 Stove Maintenance

Classic With Blower Installation and Operation Manual 28    Clearances to combustible materials and floor protection

Pagina 22

Classic With Blower Installation and Operation Manual 29 7.3 Floor protector If the stove is to be installed on top of a combustible floor, it must

Pagina 23

Classic With Blower Installation and Operation Manual 3 Table of content PART A - OPERATION AND MAINTENANCE ... 51 S

Pagina 24

Classic With Blower Installation and Operation Manual 30 7.4 Reducing Wall and Ceiling Clearances Safely It is often desirable to reduce the minimu

Pagina 25

Classic With Blower Installation and Operation Manual 31 Clearances for shield construction

Pagina 26 - 6 Safety Information

Classic With Blower Installation and Operation Manual 32 7.4.2 Table of Clearance Reduction Percentages Type of shield Clearances may be reduced by

Pagina 27

Classic With Blower Installation and Operation Manual 33 8 The Venting System 8.1 General The venting system, made up of the chimney and the conn

Pagina 28 -

Classic With Blower Installation and Operation Manual 34 8.2.2 Masonry Chimneys The stove may also be connected to a masonry chimney, provided the c

Pagina 29 - 7.3 Floor protector

Classic With Blower Installation and Operation Manual 35 8.4 The Relationship Between the Chimney and the House Because the venting system is the e

Pagina 30

Classic With Blower Installation and Operation Manual 36 8.4.2 Why the chimney should penetrate the highest heated space When it is cold outside, t

Pagina 31

Classic With Blower Installation and Operation Manual 37 8.5.1 Air Supply in Conventional Houses The safest and most reliable supply of combustion

Pagina 32

Classic With Blower Installation and Operation Manual 38 Use 45 degree elbows where possible, instead of 90 degree elbows. The rules below are bas

Pagina 33 - 8 The Venting System

Classic With Blower Installation and Operation Manual 39 • Flue pipe joints should overlap 30 mm (1 1/4 in.) • Each joint in the assembly must be

Pagina 34 - 8.3 Minimum Chimney Height

Classic With Blower Installation and Operation Manual 4 5.1.3 Replacing the Door Gasket ...

Pagina 35

Classic With Blower Installation and Operation Manual 40 Appendix 1: Installing the Fresh Air Kit (AC01337) It is possible to install a fresh air k

Pagina 36

Classic With Blower Installation and Operation Manual 41 Installation on the bottom (AC01337):

Pagina 37

Classic With Blower Installation and Operation Manual 42 Appendix 2: Use and Installation of the blower and Thermodisc A blower is installed on the

Pagina 38

Classic With Blower Installation and Operation Manual 43 CAUTION: ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE STO

Pagina 39

Classic With Blower Installation and Operation Manual 44 Appendix 3: Installation of Secondary Air Tubes and Baffle 1- Starting with the rear tube

Pagina 40

Classic With Blower Installation and Operation Manual 45 Note that secondary air tubes (A) can be replaced without removing the baffle board (B).

Pagina 41

Classic With Blower Installation and Operation Manual 46 Appendix 4: Exploded Diagram and Parts List

Pagina 42

Classic With Blower Installation and Operation Manual 47 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your

Pagina 43

Classic With Blower Installation and Operation Manual 48 # Item Description Qty 32 AC07863 1/4 " CHROME PLATED LONG COIL HANDLE 1 33 301

Pagina 44

Classic With Blower Installation and Operation Manual 49 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the orig

Pagina 45 - Model Type of tube

Classic With Blower Installation and Operation Manual 5 PART A - OPERATION AND MAINTENANCE Please see Part B for installation instructions. 1 Safety

Pagina 46

Classic With Blower Installation and Operation Manual 6 2 General Information 2.1 Classic With Blower Specifications Fuel Type Cordwood Test St

Pagina 47

Classic With Blower Installation and Operation Manual 7

Pagina 48

Classic With Blower Installation and Operation Manual 8 2.2 Zone Heating and How to Make it Work for You Your new Classic With Blower wood stove is

Pagina 49

Classic With Blower Installation and Operation Manual 9 2.4 The SBI Commitment to You and the Environment The SBI team are committed to protecting

Comentarios a estos manuales

Sin comentarios